A servo drive is the one industrial control board where analogue behaviour and switching behaviour have to coexist without corrupting each other. The board closes a current loop in tens of microseconds, drives a three-phase bridge at 8 to 20 kHz, and reads a position encoder whose resolution may be a few arc-seconds, all on a substrate that also carries the gate-drive supply. Get the return paths wrong and the design still runs — it just runs badly, with torque ripple, encoder faults at load, and nuisance overcurrent trips that nobody can reproduce on the bench.
Kilandu assembles servo drive boards as mixed SMT and through-hole builds within our industrial control PCBA operation. This page is about the build decisions that determine whether the drive you designed behaves the way you simulated: current sensing geometry, gate-drive timing, encoder routing, the brake path, and the test coverage that catches the failures which only appear at temperature or at load.
What separates a servo drive from a general motor board
A variable-frequency drive and a servo drive both switch a three-phase bridge, but they are not the same build problem. A VFD usually runs open loop or with simple slip compensation at modest switching frequency, and its dynamic requirements are modest. A servo drive is closed loop on position, velocity and current simultaneously, and the current loop bandwidth commonly sits between 1 and 3 kHz. That bandwidth is not a software parameter alone — it is bounded by how cleanly the board can measure phase current and how quickly the gate driver can turn the bridge around.
| Build aspect | General motor board | Servo drive board |
|---|---|---|
| Current loop bandwidth | 200 Hz to 1 kHz | 1 to 3 kHz, sometimes higher |
| Switching frequency | 4 to 8 kHz | 8 to 20 kHz |
| Current sensing | Single shunt or Hall on the DC link | Per-phase shunt or fluxgate, Kelvin connected |
| Encoder feedback | Rarely present | Differential or serial, up to 25 MHz clock |
| Brake path | Often external | On-board bleed resistor with software control |
| Isolation | Single barrier at the control interface | Gate-drive barriers plus encoder barrier |
Current sensing geometry decides the loop
Nearly every servo drive measures phase current across a shunt. The shunt itself is a two-terminal resistor in the schematic and a four-terminal device on the board, and the difference matters. A Kelvin connection brings two sense traces out from the inner edges of the shunt pads, routes them as a tight differential pair, and references them at the amplifier input rather than at a distant ground. If the sense traces run under the shunt body or share a return with the gate-drive loop, the amplifier sees the switching transient rather than the load current.
Two layout rules carry most of the benefit. First, the sense pair should leave the shunt perpendicular to the power flow, not parallel to it, so that the magnetic field from the high-current path induces equal voltage in both traces and cancels at the amplifier. Second, the amplifier's input filter should be placed at the amplifier pins, not at the shunt, so that the filter capacitor discharges into the amplifier input rather than into the sense trace inductance.
- Shunt placement — low-side shunts are simpler to amplify but expose the amplifier to the bridge's ground bounce; inline shunts need a high common-mode amplifier rated for the full DC link plus transient.
- Amplifier bandwidth — the current-sense amplifier needs roughly ten times the loop bandwidth, so a 2 kHz loop wants at least 20 kHz of small-signal bandwidth with settled overload recovery.
- Sample timing — sampling must land in the middle of the low-side on-time; if the ADC trigger is derived from a PWM edge rather than a timer compare, jitter turns into current noise that the loop then amplifies.
- Filter corner — an RC filter that is too aggressive adds phase lag directly inside the loop and forces the gain down, which shows up as soft response rather than as a fault.
The measurement that settles arguments: inject a step current into a blocked rotor and capture the shunt voltage and the amplifier output on the same time base. If the amplifier output rings or shows a common-mode step at the switching edge, the problem is geometry, not tuning. We have seen drives where changing only the sense-pair routing removed a 40 kHz oscillation that had been attributed to firmware for months.
Gate drive, dead time and shoot-through margin
The gate driver's job looks simple: turn the IGBT or MOSFET on and off fast, and never let both devices in a leg conduct at once. In practice the margin is set by three numbers that have to be checked together — the driver's turn-off propagation delay, the device's turn-off tail, and the dead time the controller inserts. If the sum of the first two exceeds the third at the worst-case temperature, the leg shoots through on some units and not others.
Temperature is the variable that gets missed. Gate threshold voltage falls with temperature, and switching times lengthen, so a dead time that is safe at 25 °C can be marginal at 85 °C. The practical approach is to specify dead time at the maximum junction temperature the drive will see, then verify it by measuring the bridge's DC-link current at zero modulation — a leg that is shoot-through will show a measurable increase in supply current even with no load.
| Parameter | What to check | Typical failure if missed |
|---|---|---|
| Isolation | Reinforced rating for the full DC link plus transient, not just working voltage | Barrier breakdown after a single grid transient |
| Common-mode transient immunity | Above 50 kV/µs at the rated link voltage | False gate pulses during fast switching, seen as random overcurrent |
| Desaturation detection | Blank time long enough to survive turn-on, short enough to protect the device | Device destroyed before the controller reacts |
| Gate resistor split | Separate turn-on and turn-off paths | Slower turn-off than intended, higher switching loss, more heat |
| Bootstrap or isolated supply | Undervoltage lockout at the driver, not at the controller | Partial turn-on at low link voltage, device overheating |
The encoder interface is a radio problem wearing a digital hat
An incremental encoder with 5 V differential outputs at 4 MHz is a wideband signal source sitting centimetres from a switching bridge. Most encoder faults reported as "the drive loses position under load" are not encoder failures at all — they are common-mode disturbances picked up on the A/B/Z pair and interpreted as edges. The counter then accumulates phantom counts that only appear when the bridge is actually switching.
Three build details reduce this substantially. Route the encoder pair as a true differential pair with matched length and a reference plane underneath, never as two single-ended traces that happen to run side by side. Terminate at the receiver with the value the encoder datasheet specifies, and place the termination at the receiver pins. Finally, put the encoder receiver behind its own isolated supply domain if the encoder cable leaves the enclosure — a long cable to a motor-mounted encoder is an antenna, and the isolation barrier stops the disturbance from reaching the controller ground.
- Serial encoders (BiSS, SSI, HIPERFACE-style) carry a clock as well as data; clock return must be routed as part of the pair, and cable delay has to be inside the protocol's tolerance.
- Resolver interfaces need an excitation amplifier and a synchronous demodulator; the excitation return must not share copper with the logic ground.
- Absolute multiturn encoders with battery backup bring a separate failure mode — a dead backup cell shows up as a position jump at power-up, not as a communication error.
The brake path is a thermal problem, not a circuit problem
When a servo decelerates a load with inertia, the motor becomes a generator and pushes energy back into the DC link. Above a threshold the link voltage rises past the capacitor rating, so the drive switches a bleed resistor across the link. The switching device and the resistor are usually correct in the schematic. What fails in the field is the thermal budget around them: the resistor is mounted where convection is blocked, the switching device's thermal pad is sized for average rather than pulse current, and the board's copper under the resistor is thinner than the pulse energy requires.
Two questions decide the build. What is the worst-case regenerative energy in a single deceleration, and what is the duty cycle of repeated decelerations? The first sets the resistor's pulse rating; the second sets its average rating and the copper area that spreads heat into the board. A drive that is fine in a single-cycle test can still cook its bleed resistor in a machine that indexes every 400 ms.
Ask for the motion profile, not just the motor rating. We have quoted builds on motor power alone and later found the application cycled at a rate that quadrupled the average brake dissipation. The bleed resistor, its switching device and the copper around them are the parts that have to change, and they are the parts that are hardest to change after the board is released.
Mixed SMT and through-hole on the same substrate
A servo drive typically carries fine-pitch logic, a gate-drive section with creepage requirements, and power terminals that must survive several newton-metres of torque. Those three requirements pull in different directions. Fine-pitch parts want reflow with tight placement tolerance; the isolation barrier wants slotting or a milled gap; the power terminals want selective solder with enough barrel fill to carry the current.
Our standard route is reflow for the SMT assembly side, then selective solder or wave for the through-hole power section, with the isolation barrier's creepage and clearance verified against the drawing after assembly rather than assumed from the stencil. Conformal coating, where the environment requires it, is applied after test with the connectors masked — see our PCBA testing and quality assurance pages for how the coated and uncoated states are handled in inspection.
What we test, and why each test earns its place
A servo drive that passes a bare power-on test can still fail on the machine. The tests worth running are the ones that separate a board which works on the bench from one that works at temperature and at load.
| Test | What it catches | When it must run |
|---|---|---|
| Gate-drive timing (dead time, propagation) | Shoot-through margin, asymmetric switching | Every unit, at temperature |
| Current-sense offset and gain | Loop offset that becomes torque ripple or drift | Every unit, at two temperatures |
| Encoder interface loopback | Missing edges, termination error, clock return | Every unit, at maximum clock |
| Isolation barrier test | Barrier integrity after assembly | Every unit |
| Loaded run with a real motor | Thermal behaviour of the bridge and the brake path | Sample per lot, plus first article |
| Thermal cycling of the power section | Solder fatigue at the terminals and the shunt | Design validation, not production |
| In-circuit test | Wrong value, missing part, orientation | Every unit, where the fixture exists |
We build test coverage around what the customer can measure, not what is convenient for us. If the drive's own firmware can report bus voltage, phase current and encoder status over its service interface, that becomes the functional test — because it exercises the same path the machine will use. Details of our test approach are on the PCBA testing page, the specific measurements are listed in test methods, and the acceptance criteria we work to are described under IPC-A-610. It is maintained by IPC, now the Global Electronics Association, and the published table of contents shows how those criteria are organised.
Component sourcing and the ten-year availability problem
Industrial drives stay in production far longer than consumer products. A machine tool built in 2026 may still be shipping in 2036, and the customer expects to buy the same drive. That makes part selection a build decision rather than a purchasing decision: a gate driver that is second-sourced, a shunt with a stable temperature coefficient, and an encoder receiver still available in the package you qualified matter more than a few cents of unit cost.
We flag single-source parts at quotation, and we keep the approved-vendor list and the last-purchased date for every line so that a substitution can be evaluated against the original qualification rather than against the cheapest available equivalent. See component sourcing for how consigned and turnkey material are separated, and turnkey PCBA for the scope of a fully sourced build.
What we need to quote a servo drive build
Quotations on drive boards go wrong when the power section is quoted as if it were a logic board. The inputs that change the number are specific.
- BOM with approved alternates — especially for the gate driver, the shunt and the encoder receiver.
- Gerber and drill data, plus the stack-up if the isolation barrier relies on a specific layer arrangement.
- Copper weight and layer count, because a 2 oz inner layer changes both etch tolerance and price — see multilayer PCB and PCB fabrication.
- Isolation requirement — working voltage, transient level, and whether reinforced clearance is needed across the barrier.
- Terminal and connector torque spec, which determines whether selective solder is required.
- Test specification — which of the tests above are per-unit and which are sample-based.
- Annual volume and expected production life, because the last-time-buy risk sits with the parts chosen now.
Our quotation file checklist lists the complete set. If the file set is incomplete we will say which item is missing and what it changes, rather than quoting a number that has to be revised. A DFM review runs before quotation on any board with a fine-pitch driver. For volume bands and lead times see MOQ and lead time, and the assembly cost calculator gives an indicative range before a formal quote.
How a servo drive programme usually starts
Most of the drives we build begin as a prototype batch of 5 to 20 boards, built on the same line and with the same stencil as the production run that follows. The point of building the prototype on the production route is that the process-related surprises — tombstoning on the fine-pitch driver, wicking in the power terminals, coating creep into the connector — show up while the quantity is still small enough to change the design.
From there the usual sequence is a small pilot lot at the customer's real test specification, then a production release with the approved-vendor list frozen. Boards that involve a first-article inspection follow the flow described on quality assurance, and where the drive is part of a larger cabinet the sub-assembly scope is covered by box build.
Where this board sits in a machine
A servo drive rarely ships alone. It sits next to the PLC CPU module that sequences the machine, below an HMI touch panel that the operator uses, and alongside the motion controller that issues the position commands. In a CNC application the drive is one axis among several coordinated by the CNC controller. In textile machinery the same drive type runs many axes in parallel under a textile machine control board, where the failure mode that matters is drift across axes rather than absolute accuracy on one. Where the drive is part of a lift system, the safety architecture is different again — see elevator control PCB.
Understanding that context changes what we test. A drive destined for a multi-axis textile line gets a longer loaded run and a cross-axis repeatability check, because a single axis that is 0.2 % off passes every individual test and still produces off-spec fabric. Where the drive is the only board in the cabinet, the quotation usually combines fabrication, assembly and test — the turnkey route — and the reasons customers choose that over a split supplier chain are set out on why choose Kilandu.
Questions we are asked before a servo drive quote
Can you assemble a drive board with an isolated gate driver and 2 oz copper?
Yes. Heavy copper on inner layers and isolated gate drivers are both within our normal range. The constraint is etch tolerance on the heavy layers, which affects minimum spacing rather than feasibility. See heavy copper PCB for the fabrication side.
Do you supply the power stage components, or do we consign them?
Either. Consigned power devices are common on drive programmes because customers qualify specific parts. We separate consigned and turnkey material explicitly so the quotation shows which is which — see component sourcing.
How do you handle the encoder cable that leaves the enclosure?
The interface is built and tested at the board, including the isolated domain and the termination. What happens beyond the connector depends on the customer's cable and shielding, which we ask about because it determines whether the receiver needs additional common-mode filtering.
What is the smallest quantity you will build?
Prototype quantities start in the single digits. The economics depend on the stencil, the test fixture and the terminal applicator rather than on the board count, which is why we quote those separately. See MOQ and lead time.
Can you test the drive against our firmware?
Yes, when the firmware and the service interface are available to us. Testing against the customer's firmware is more informative than testing against a generic harness, because it exercises the same code path the machine will use. Where firmware cannot be shared, we test the hardware interfaces and report the boundary clearly.
Send the BOM, the Gerber set and the motion profile.
We will come back with the parts that need an approved alternate, the tests we recommend per unit versus per lot, and a quotation that separates the power section from the logic section.
Start a servo drive quotation · What to send · Industrial control PCBA