AC EV Charger PCBA

An AC charging station does not rectify anything. It is an intelligent, protected switch: it decides whether the vehicle may draw current, tells the vehicle how much it may draw, measures what was drawn, and opens the contactor when something goes wrong. That makes an AC charger PCBA a different build problem from a DC fast charger board. There is no high-frequency power stage and no large heatsink, but mains voltage sits on the same board as a 3.3 V microcontroller, and every protection function has to be demonstrable rather than merely present. Kilandu assembles AC charger control boards as mixed SMT and through-hole builds within our EV charger PCBA operation.

What an AC charger board actually does

The power path in a Mode 3 AC station is short. Mains enters, passes through a residual-current device and a contactor or relay, and leaves through the vehicle connector. Everything else on the board exists to supervise that path. In practice the board carries five jobs at once:

  • Session control. Generate the control pilot waveform, read the proximity pilot, run the state machine, decide when the contactor may close.
  • Metering. Measure voltage and current on the live conductors to a declared accuracy, and hand the energy register to the backend.
  • Protection supervision. Residual current, over-current, over and under-voltage, earth continuity where the design calls for it, and the contactor feedback that proves the switch actually opened.
  • User and network interface. RFID reader, display or LED indication, and the link to the operator over OCPP.
  • Actuation. Contactor coil drive, connector lock solenoid drive, and the interlock that prevents closing into a fault.

On a 7 kW single-phase wallbox these five jobs often sit on one board. On a 22 kW three-phase public pillar they are usually split across a controller board, a power and metering board, and a separate display or RFID board. Both arrangements are assembled on the same lines; the difference is in the connector count and in how the isolation barrier is drawn.

Board-level architecture and what each block demands

Function blockTypical contentManufacturing consequence
ControllerMCU or SoC, external flash, RTC, watchdog, isolated supplyFine-pitch SMT, programming and read-back per unit
Control pilot interfacePWM generator, level shifting to ±12 V, comparator feedback, protective dividerAnalogue tolerances matter more than placement density; verified at functional test
MeteringShunt or current transformer, metering IC, precision reference, isolationCalibration and temperature drift check; the accuracy claim is only as good as the calibration record
Residual current detectionType A or Type B module, or a 6 mA DC detection stage, plus the trip pathMixed technology; the trip path is a functional test item, not a continuity check
SwitchingContactor or relay, coil driver, flyback suppression, feedback contactThrough-hole, wave or selective soldered; contactor mass needs mechanical support
Lock driveSolenoid driver, current limit, position feedbackInductive load; suppression and inrush behaviour are checked on the assembled board
Communication4G module, Ethernet PHY and magnetics, Wi-Fi module, RS-485, RFID front endShielded sections, antenna keep-out, module-level test after assembly
User interfaceDisplay connector, LED drivers, buttons, buzzerConnector and cable-side retention checked before shipment

The isolation barrier is the design, not a detail

Most AC charger boards that fail a design review fail here. The mains side and the control side share a board, and the distance between them is not a single number that can be copied from another project. Creepage and clearance are derived from the working voltage, the pollution degree inside the enclosure, the over-voltage category and the material group of the laminate, following IEC 60664-1. A board designed for a sealed indoor wallbox and a board designed for a vented outdoor pillar with condensation are not the same board even when the schematic is identical.

Four things we check at DFM review before the first build:

  1. Slot and cut-out versus coating. A milled slot increases creepage on paper but a conformal coating that bridges it gives the distance back. The two measures have to be designed together, not added independently.
  2. Contactor and terminal spacing. The through-hole footprints of mains terminals often sit closer than the board-level clearance allows, because the footprint was taken from the component datasheet rather than from the isolation requirement.
  3. Copper at the barrier. Inner-layer copper that crosses under the barrier defeats an outer-layer slot. We check every layer, not only the top.
  4. Test points at mains potential. A test pad inside the barrier is a creepage reduction and a service risk. Where functional test needs access, it is planned at the fixture side.
When a customer sends a board that already passed certification in another factory, we still re-check the barrier against the actual stack-up. A layer count change, a laminate change from FR-4 to high-Tg FR-4, or a switch to a thicker copper inner layer can all move the distance that was qualified.

Current path and copper weight

A 32 A single-phase station carries 32 A continuously through the board, and a 22 kW three-phase unit carries roughly 32 A per phase. Continuous current, not peak current, sets the copper. We size the power tracks from the current and the permitted temperature rise in the enclosure, then check the result against the connector rating rather than the other way round.

For boards above the current that 2 oz copper can carry comfortably, the options are heavier inner layers and local copper blocks. Our heavy copper capability starts at 2 oz and runs to 6 oz as a typical working range for power layers, with 3 to 20 oz copper blocks used locally where the current concentrates at a terminal. The limit is not the plating but the minimum trace width that can still be etched reliably at that thickness, which is why the conversation has to include the artwork rather than only the current figure.

Residual current protection: the part that is most often specified wrong

An AC charging station has to detect DC residual current that a conventional Type A device cannot see. A vehicle on-board charger can inject smooth DC into the protective conductor, and above a few milliamps that saturates the Type A core so it stops responding to AC faults. The design therefore uses one of three arrangements: a Type B device, a Type A device plus a separate 6 mA DC detection module, or an integrated module that provides both.

From an assembly standpoint the three are not equivalent. A Type B device is a large through-hole component with its own terminals and a defined mounting orientation. A 6 mA DC module is usually a small board or a potted block with flying leads that has to be positioned so its leads do not cross the mains barrier. Either way, the trip path is verified as a function — we inject a simulated residual current at the specified threshold and confirm the contactor opens within the specified time — rather than checking that the module is populated.

Control pilot and proximity pilot

The control pilot is a 1 kHz PWM signal at ±12 V that tells the vehicle the available current, and the vehicle answers by changing the voltage level on the same wire. The proximity pilot is a resistive divider in the connector that tells both sides the cable rating and whether the latch is engaged. Both are analogue interfaces sitting next to a switching contactor, and both are where intermittent field faults originate.

We treat them as measured functions. The test fixture loads the pilot line at the levels corresponding to the states the customer specifies, and the firmware response is checked at each transition rather than at a single steady state. A board that passes at the "connected" level but not at the "charging" level is a board that will strand a customer at the station.

Contactor, relay and lock drive

These parts are the reason an AC charger board is a mixed-technology build. A 32 A contactor is a through-hole device with terminals that carry mains current; a lock solenoid is an inductive load with inrush several times its holding current. Both are placed after the SMT reflow step so the reflow profile does not have to accommodate their mass, and the fine-pitch control side is protected during wave or selective soldering.

Three build details decide whether the actuation side survives:

  • Contact feedback. Where the contactor provides an auxiliary contact, it is wired to a supervised input. A stuck contactor that reports "open" is worse than one that fails to close, so the feedback path is tested in both states.
  • Suppression placement. Flyback or RC suppression across the coil has to sit at the coil, not at the driver, or the transient is radiated across the board instead of being absorbed.
  • Mechanical support. A contactor heavier than roughly 30 g needs more than solder joints to survive transport. We raise the need for a bracket, a retaining clip or a staking point at DFM, and through-hole assembly plans the support into the build.

Assembly constraints we work to

ParameterCapability
Board typeMixed SMT and through-hole, single or double sided
Layer count2 to 24 layers; 4 and 6 layer control boards are the common case
Minimum trace and space3 mil / 3 mil on ½ oz copper
Copper weight1 oz signal, 2 oz to 6 oz on power layers, copper blocks 3 to 20 oz locally
Fine pitch0.4 mm QFP, 0.5 mm pitch QFN, BGA down to 0.4 mm pitch
Through-holeWave or selective soldering; press-fit terminals on request
Surface finishENIG, immersion silver, OSP, hot-air levelling
CoatingAcrylic, polyurethane or silicone, with masking to the assembly drawing

Bare boards come from our own PCB fabrication operation, which matters on this product family: when the barrier spacing or the copper weight has to change, the fabrication and assembly sides are looking at the same stack-up instead of negotiating over a purchase order. Multi-layer control boards follow the rules on our multilayer PCB page.

Coating for garages, car parks and coastal sites

An AC wallbox in an underground car park sees humidity cycling and condensation on cold mornings. A pillar on a coastal site sees salt in the air. Both are addressed with conformal coating rather than with a sealed enclosure alone, because the enclosure breathes as it heats and cools.

We apply acrylic, polyurethane or silicone coating to the areas the assembly drawing designates, with connectors, terminals, test points and mating surfaces masked. The masking plan is agreed before the first build: coating a contactor terminal block or a pilot test pad creates a service problem that is invisible until someone tries to probe it. The conformal coating page sets out the masking options and the inspection criteria for coverage.

Test plan: what has to be proven before shipment

The test list on a charger board is chosen by which failures matter, not by what the fixture happens to support. Our standard route is SPI before reflow, AOI after placement and after reflow, X-ray on selected builds, ICT for assembly integrity, then functional test against the agreed specification.

TestWhat it provesNotes
SPISolder paste volume and coverageEvery reflow pass
AOIPresence, polarity, placement, joint qualityAfter placement and after reflow
X-rayHidden joints: BGA, QFN, power device thermal padsSelected builds, or every unit where the design requires it
ICTOpens, shorts, component valuesBefore any functional exercise
Programming read-backFirmware actually written and correctRecorded per unit
Pilot and proximity pilotState transitions and current-limit signallingLoaded at the customer-specified levels
Residual current tripThreshold and trip time of the protection pathSimulated residual current
Contactor and lock driveClose, open, feedback in both states, lock engage and releaseSeparate from the protection test so failures are attributed correctly
Metering accuracyVoltage, current and energy against a referenceReported per unit where the customer's metering claim depends on it
CommunicationLink established and session exercised over the interface fittedNot a continuity check

Test limits, fixtures and pass/fail records are agreed before production and then held. Repeat orders run to the same limits as the approved first article. The PCBA testing page describes fixture building and program development, and this answer on production testing explains what each method actually catches.

Where AC charger builds go wrong

  • Barrier distance qualified on a different stack-up. A laminate change or a layer count change moves the distance without changing the schematic.
  • Coating over a service point. The board passes test and cannot be diagnosed in the field.
  • Pilot line tested at one state only. The station works on the bench and fails at the "vehicle requests current" transition.
  • Contactor mass unsupported. Solder joints crack in transport and the station reports a switching fault on arrival.
  • Metering accuracy claimed from the IC datasheet. The declaration is only as good as the calibration and the drift check behind it.
  • Alternative component fitted without written approval. On a charger board a substitution can invalidate certification evidence, not just the build record.

What we need to quote an AC charger board

Gerber files with drill data and board outline, a BOM with manufacturer part numbers, the AC configuration (single or three phase, current rating), the protection arrangement, the communication interface, the enclosure or mechanical interface, the expected quantity and the acceptance class. Where functional test is required, the test specification and any existing fixture documentation shorten the quote cycle considerably. The quotation file checklist lists the full set.

Prototype builds run in 5 to 8 working days with components in stock, volume production in 2 to 5 weeks, and repeat orders to an approved build in 2 to 3 weeks. Component availability is usually the binding constraint rather than machine time. There is no fixed minimum order quantity; the variables that move the number are set out on the MOQ and lead time page. For a first cost indication before files are ready, the assembly cost calculator gives a range and the cost breakdown explains what drives it.

Frequently asked

Can you assemble both the AC and the DC board for one charging product?

Yes, and it is common. The AC side control board and the DC side power and control boards are built on the same lines, so one production record covers the unit. See the DC fast charger PCBA page for the power-side differences.

Do you supply the contactor and the residual current device, or do we consign them?

Either. We source through our normal component sourcing channel, or build with customer-consigned parts against the approved-vendor list. Long-lead and allocation-risk items are flagged at quotation, and nothing is substituted without written approval.

Is the metering calibrated on your line?

We verify metering against a reference at functional test and record the result. Whether that constitutes a calibrated energy declaration depends on the accuracy class the customer is claiming and on the traceability of the reference; that is agreed at quotation rather than assumed.

What happens if the enclosure changes after the first build?

The board-to-enclosure interface usually changes with it: connector positions, the lock mechanism and the coating masking all move. We re-run DFM against the new drawing rather than carrying the previous build's assumptions forward. Where the change also affects the isolation distance inside the enclosure, the barrier is re-checked.

Why Kilandu for AC charger boards

Bare board and assembly sit under one quality system, certified to IATF 16949:2016 (certificate 0596984), ISO 9001:2015 (CN27125Q0392R0S), ISO 13485:2016 (35825MDQMS0021R0S) and ISO 14001:2015 (CN27125E0142R0S), with UL file number E352816. Acceptance criteria are stated by IPC-A-610 class rather than as a general claim, and the inspection gates are described on the quality assurance page. Boards can be supplied as an assembly or as a box build with harness, labels and packaging, and full turnkey scope including sourcing is covered under turnkey PCBA.

Send an AC charger board for review. Gerbers, BOM, the current rating and the protection arrangement are enough for a DFM report and a price against your quantity.