Kilandu sales team exchanging business cards with a European PCBA customer
PCBA Answers

How do you choose a PCBA supplier for BMS and energy storage boards?

Short answer. A BMS board is judged on measurement accuracy and protection behaviour, not on placement quality alone. Choose a supplier that can state which cell counts it builds, how the current-sense path is laid out, which protection functions are actually tested and at what thresholds, and whether the calibration and test record is tied to the unit or to the lot.

Start with the cell count, not the price

Cell count drives the board. More cells means a wider measurement range, more sense lines, a higher cell-monitor channel count and different protection thresholds, so each configuration is a design rather than a variant of one page. A supplier that quotes a 16S pack from an 8S process without re-reviewing the sense network is quoting a board it has not designed.

Kilandu builds 4S, 8S, 10S, 12S, 13S and 16S configurations. The cell-count index used at quotation is on the BMS PCBA page, and configurations outside that range are reviewed as their own design.

The four technical questions that separate suppliers

  • Where does the current-sense path run? A shunt or hall measurement loop that shares a return with the switching node will read the switching, not the current. Ask how the sense loop is kept out of the power path and how the analogue ground is returned.
  • How is cell voltage accuracy held across the pack? Accuracy at nominal is easy. Accuracy at the top and bottom of the pack range is where sense-line routing and divider tolerance show up.
  • Which protection functions are tested, and at what threshold? Over-charge, over-discharge and over-current protection each need trip and recovery verification, not a single pass/fail at one point.
  • Is calibration recorded per unit or per lot? A per-unit record is what makes a field return diagnosable.

What the test sequence should cover

On a BMS build the electrical test is not a single step. It typically runs: in-circuit test on the assembled board, functional test including cell-voltage accuracy across the pack range and current measurement in circuit, protection-function verification with trip and recovery at the specified thresholds, programming and read-back where firmware is loaded, and burn-in under load for the agreed period. AOI and X-ray cover the joints that cannot be seen; they do not cover the measurement chain.

A supplier that describes only AOI and a power-on check has described assembly, not verification.

Records and traceability

Energy storage packs carry a service life measured in years, and a field failure has to be traceable back to a lot. Ask what is retained: incoming material records, the test result per unit, the firmware version shipped, and the calibration data. Ask how long it is retained, and ask to see a sample record before you place the order rather than after the first failure.

The build, in figures

4S, 8S, 10S, 12S, 13S and 16S configurations, on 4 Yamaha SMT lines and 3 DIP lines running 150 million points per month. The same lines carry 01005 placement and 0.25 mm pitch, so a sense network that needs fine pitch does not move the board to a different factory. A BMS build follows the same 2 to 5 week window as any other turnkey board, with prototypes at 5 to 8 working days when the material is in stock.

On the quality side the figures are the ones a tender asks for: ISO 9001:2015 under CN27125Q0392R0S, IATF 16949:2016 under 0596984, ISO 13485:2016 under 35825MDQMS0021R0S and UL file E352816. The scope and validity of each are published on the quality assurance page, including the part of the work the IATF scope excludes.

Six questions, and the answer that carries a number

What to askAnswer that commits to nothingAnswer worth having in writing
Cell count“We build BMS boards”The configurations actually built - 4S, 8S, 10S, 12S, 13S, 16S - and how anything outside that range is handled
Current-sense path“Layout is reviewed”How the sense loop is kept out of the power path, and how analogue ground is returned
Voltage accuracy“Accuracy is good”The accuracy held at the top and bottom of the pack range, not only at nominal
Protection functions“Protection is tested”Trip and recovery thresholds for over-charge, over-discharge and over-current, each verified
Calibration record“We calibrate”Per unit rather than per lot - the only form that makes a field return diagnosable
Test sequence“AOI and a power-on check”ICT, functional test across the pack range, protection verification, programming read-back, burn-in

A supplier that describes only AOI and a power-on check has described assembly, not verification of the measurement chain.

What Kilandu does on a BMS build

Kilandu assembles BMS boards on four Yamaha SMT lines and three DIP lines in Shenzhen, with SPI, AOI and X-ray in process and ICT plus FCT in electrical test. On request the voltage and current paths are calibrated and recorded per unit, and per-lot records cover the specific cell count and firmware version shipped. Builds inside a medical device follow the ISO 13485 management system; automotive programmes are quoted against the automotive flow rather than the general one.

Where the detail is documented

The full BMS guide, including the 16S energy-storage case study, is on the BMS PCBA page, and the same build is written up on the BMS case study page. Certification scope is on the quality assurance page. Send the pack specification, cell count and protection thresholds to alden@kilandu.com for a design review before quotation.