Portable EV Charger PCBA

A portable EV charger is the hardest packaging problem in the charger family. The same functions that fill a wall-mounted box are compressed into an in-cable control box that hangs from a socket, gets dropped, gets left in a car boot through a winter, and has to hold its protection thresholds without a fan and without a metal enclosure to spread the heat. It is also the product with the smallest board area per watt, which means every square millimetre of copper is doing two jobs at once. Kilandu assembles portable charger boards within our EV charger PCBA operation.

What a portable charger actually is

A portable unit — an in-cable control box used with a domestic socket — is not a small wallbox. Three differences matter for the build:

  • The plug is part of the product. The temperature sensor that protects the wall socket sits in the plug, not on the board, and its signal runs the length of the cable into an analogue input on a board that also carries a switching relay.
  • There is no thermal path out except the housing. A wallbox can use the wall and the metal bracket. A portable box has a plastic enclosure and the surrounding air, so the board becomes a heat spreader by necessity.
  • The product is handled. It is dropped, coiled, stood on and stored in a car. Solder joints, terminal screws and connector retention are all mechanically loaded in a way that a fixed installation never sees.

The board therefore carries a full protection set in a fraction of the area, and the design compression is what makes it a different manufacturing problem rather than a smaller version of the same one.

Board content and layout pressure

BlockContentWhy it is tight
Control and state machineMCU, pilot signal generator, level shifting, protection logicShares the board with mains switching; isolation has to be maintained in a small footprint
SwitchingRelay or contactor, coil driver, contact feedbackLargest single component; mechanical mass on a board that gets dropped
Residual current protectionType A device plus 6 mA DC detection, or an integrated moduleBulky, often the tallest part, and its leads must not cross the barrier
Temperature sensingPlug sensor input, board sensor, power device sensorLow-level analogue next to switching; filtering and return path decide accuracy
MeteringShunt or current transformer, metering ICKelvin routing in a space that has none to spare
User interfaceLEDs or a small display, button, buzzerFront-panel alignment is a mechanical requirement, not a schematic one
SupplyIsolated or non-isolated auxiliary rail, supervisorBrown-out and inrush behaviour matter on a plug-in product
Communication (where fitted)Wi-Fi or Bluetooth for app controlAntenna keep-out in a plastic box with a metal relay inside

Most portable designs are two-layer or four-layer boards, and the copper on the mains side is doing thermal work as well as electrical work. That combination — thin board, heavy copper, high current, small area — is where the thermal design and the mechanical design have to be solved together.

Heat without a fan

A 7 kW portable unit dissipates somewhere between 100 and 250 W depending on the topology, and all of it leaves through the enclosure surface. There is no fan to force air and no cold plate to conduct into. The board's contribution is to spread heat from the switching devices and the relay terminals into as much copper as the area allows.

What that changes in the build:

  • Copper weight above the default. Power layers run at 2 oz and upwards; where the area is very tight, local heavy copper or a copper block is used to move heat away from a device footprint. Our heavy copper range covers 2 oz to 6 oz as a typical working range, with copper blocks from 3 to 20 oz used locally.
  • Thermal vias under devices. Vias transfer heat to the opposite side of the board, where the copper can spread it. They have to be filled or capped before assembly or the solder wicks away from the joint.
  • Relay terminal temperature. The relay terminals are often the hottest point in the box, not the semiconductors, because the current density is highest there. Copper around the terminals and the terminal's own cross-section decide whether the enclosure passes a temperature-rise test.
  • Laminate choice. A small hot board benefits from high-Tg laminate for dimensional stability, and from a finish that survives repeated thermal cycling without a change in contact resistance.
We ask for the permitted enclosure surface temperature and the ambient the product is rated for, not for a junction temperature. The junction figure follows from the thermal path the customer has designed; the surface figure is what the standard tests and what the user actually touches.

The plug temperature sensor

This is the detail that separates a portable charger from every other board in this family. The plug contains a temperature sensor — usually a thermistor — that detects a poor contact in the wall socket before it becomes a fire. Its wiring runs several metres through a cable that is flexed thousands of times, and it terminates on the board at an analogue input a few millimetres from a relay coil.

The failure modes are all at the interface rather than in the silicon:

  • Open circuit from cable flex. The board reads a very low temperature and the protection never trips. Designs normally detect an open sensor explicitly; whether that detection is exercised at test is the manufacturing question.
  • Noise from the relay coil. A coil switching nearby induces a transient into the sensor line. Filtering at the connector and a defined return path are what stop it; a filter placed at the MCU pin instead of at the connector lets the noise travel first.
  • Calibration across the cable. The reading depends on the sensor's tolerance and on the cable resistance. Where the customer's specification gives a trip threshold in degrees, the tolerance stack has to be checked, not assumed.

We verify the sensor input at functional test with a substituted resistance at two points, so the reading path is exercised through the connector rather than at a test pad on the MCU side. That is a small change in fixture design and a large change in what the test proves.

Dropped, coiled and stored: mechanical load

A portable box is a handled object. Three mechanical requirements come out of that and all three are decided at assembly rather than at design review:

  1. Relay and contactor retention. A part with significant mass held only by solder will crack joints under repeated impact. Where the enclosure provides a rib or a clip, we check that the assembled height puts the part in contact with it; where it does not, we raise the need for a retaining compound or a staking point at DFM. Staking is a process we run.
  2. Terminal screw and cable gland torque. The mains terminals are tightened by the user or the installer. A terminal that turns in its footprint under torque is a field failure; the footprint's mechanical anchoring is part of the artwork.
  3. Connector retention. The cable enters the box through a gland and terminates on the board. Any movement that reaches the solder joint is a fatigue crack waiting to happen, so strain relief is a requirement of the assembly rather than a nicety of the enclosure.

Moisture, condensation and coating

A portable charger lives in a car boot, gets used in rain, and moves between cold and warm environments. Condensation on a board that carries mains is a creepage problem as well as a corrosion problem.

We apply acrylic, polyurethane or silicone conformal coating with masking to the assembly drawing: terminals, test points, the relay contact area, the plug sensor connector and any mating surface stay clear. The conformal coating page sets out the masking rules and the coverage criteria.

Coating is not full embedding. A portable design that requires the board to be embedded in a resin compound for isolation or thermal reasons is asking for a process we do not offer, and the requirement has to be raised at quotation so the scope can be discussed rather than discovered at the first build.

Isolation in a small footprint

Every distance requirement that applies to a wallbox applies here, in less area. The usual compromises and their consequences:

  • Slots instead of distance. A slot increases creepage without increasing board size, but it weakens a board that is also being dropped, and it has to be checked on every layer including the inner ones.
  • Coating credited as a distance measure. Possible under some conditions, but only where the coating type, thickness and coverage are controlled and documented. We treat it as a process with an inspection criterion, not as a claim to be written into a datasheet.
  • Sensor and signal routing across the barrier. The plug sensor line, the pilot line and the LED wiring all cross from the mains side to the control side. Each crossing is a barrier point and each needs its own treatment.
  • The relay itself. A relay provides isolation across its contacts, but only to the rating of the part, and only when the contact gap is intact. A welded contact removes the isolation and the protection at the same time, which is why contact feedback is not optional on this product.

All of this is reviewed at DFM review against the actual stack-up. Multi-layer portable boards follow the rules on the multilayer PCB page.

Assembly constraints

ParameterCapability
Layer count2 to 24 layers; 2 and 4 layer portable boards are the common case
Copper weight1 oz signal, 2 oz to 6 oz on power layers, copper blocks locally
Board thickness0.8 mm to 2.0 mm typical; thicker where mechanical stiffness requires it
Minimum trace and space3 mil / 3 mil on ½ oz copper
Double-sided assemblySupported; the second side is reflowed with the first side held by adhesive or by a reflow carrier
Through-holeWave or selective soldering for relays and terminals
StakingAvailable for parts that need mechanical support beyond solder
CoatingAcrylic, polyurethane or silicone with masking

Double-sided assembly is normal on this product because the area is not there to put everything on one side. That introduces a second reflow pass over parts that were already soldered, so the profile and the component selection have to tolerate it — a part that is only rated for one reflow cycle cannot be used on the side that goes through twice.

Test plan

TestWhat it establishes
SPI and AOIPaste volume and placement on both sides, joints on visible pins
X-rayHidden joints on selected builds; voiding under power devices
ICTOpens, shorts, values, including the sensor input path to the connector
Programming read-backFirmware written and verified, recorded per unit
Pilot signalPWM levels and duty at the states the customer specifies
Residual current tripThreshold and trip time by simulated residual current
Plug sensor simulationReading at two substituted resistances, through the connector
Relay drive and feedbackClose, open, and feedback in both states
Loaded functional testOperation at a specified load with temperature monitored
Temperature riseEnclosure or terminal temperature at rated current, where the programme specifies it

The loaded test is where a portable design usually reveals itself. A board that passes at no load and drifts at rated current has a thermal or a sensing problem, and finding it in the factory is considerably cheaper than finding it in a customer's garage. Fixtures for loaded testing are built to the customer's specification — the PCBA testing page covers fixture and program development, and this answer explains what each method catches.

Where portable builds fail

  • Plug sensor open circuit not detected. The protection is present and inert.
  • Relay mass unsupported. Joints crack in transit and the unit fails on arrival.
  • Second reflow over a one-cycle part. A component that was never qualified for two passes fails a month later.
  • Terminal footprint that turns under torque. The installer's wrench damages the board and the fault appears at the customer.
  • Coating on the plug sensor connector. The reading drifts and the trip threshold is never reached.
  • Antenna keep-out ignored in a metallised box. App control works on the bench and not in the enclosure.

What we need to quote

Gerbers with stack-up, the BOM with manufacturer part numbers, the rated current and the input configuration, the protection arrangement, the plug sensor type and its wiring, the enclosure drawing including the mechanical retention features, the cable and gland arrangement, the expected quantity and the acceptance class. Where the product carries a wireless interface, the antenna keep-out drawing matters as much as the schematic. The quotation file checklist lists the set.

Prototype builds run in 5 to 8 working days with components in stock, volume production in 2 to 5 weeks, and repeat orders in 2 to 3 weeks. There is no fixed minimum order quantity. Relays, residual current modules and connectors are the usual scheduling constraints, so sourcing is settled at quotation — see component sourcing and the MOQ and lead time page. The assembly cost calculator gives a first indication and the cost breakdown explains the drivers.

Frequently asked

Can you build the complete portable unit, not only the board?

Yes, as a box build: the enclosure, cable, gland, labels and packaging are assembled around the tested board. The enclosure and cable are supplied to us; we assemble and test, and we do not manufacture the housing.

How is the plug sensor tested if the plug is not supplied?

With a substituted resistance at the connector, at two points, so the reading path from the connector to the firmware is exercised. If the customer supplies the cable assembly, the same test runs against the real sensor and the reading is compared with the cable's declared tolerance.

Do you coat the whole board?

No. Coating follows the assembly drawing: designated areas only, with terminals, test points, the relay contact area and the plug sensor connector masked. Full coverage would make the product unserviceable and would change the thermal behaviour.

What is the difference between this board and the AC wallbox board?

Packaging and mechanical load, mostly. The functions overlap but the portable board has less area, no metal enclosure to spread heat, a plug sensor that has to survive cable flex, and a product that is dropped. The AC EV charger PCBA page covers the fixed-installation case.

Why Kilandu

Fabrication and assembly under one quality system: IATF 16949:2016 (0596984), ISO 9001:2015 (CN27125Q0392R0S), ISO 13485:2016 (35825MDQMS0021R0S), ISO 14001:2015 (CN27125E0142R0S), UL E352816. Acceptance is stated by IPC-A-610 class, the inspection gates are on the quality assurance page, and capacity is on factory capabilities. A full turnkey scope covers sourcing, fabrication and assembly together.

Send the board and the enclosure drawing together. On a portable product the mechanical retention and the antenna keep-out are decided as much by the housing as by the board.

Contact the engineering desk · EV charger PCBA overview · Charging pile controllers · Why Kilandu